What was found
CORROSION ON FRAME BS 1022 BETWEEN LONGERON 20 RT TO 26 RT AT AFT CARGO COMPARTMENT, C2,SM, CARD 10, ZONE 180. CORROSION WAS REMOVED, REWORKED AREA WAS MEASURED, TREATED, AND PAINTED IAW SRM 51-10-04, PAR 26, 21 AND 5. ORIGINAL THICKNESS: 0.063", REMAINING THICKNESS: 0.056". THEREFORE ITS WITHIN LIMITS IAW SRM 53-00-00, FIG 103. PREVIOUS STRAP ON FRAME WAS REPLACED IAW SRM 53-20-07, FIG 201 AND 51-41-02. EQUIPMENT: OLYMPUS NDT 35DL SONOPEN V-260 SM EXP DATE: 08-DEC-16. RII COMPLETED.