What was found
CRACK ON STIFFENER OF BS 1338 AND PROJECTION LONG 15RT AT RT AFT LAVATORY AREA. STIFFENER ABOVE REPORTED WAS DRILLED, TREATED, PAINTED AND REPLACED IAW SRM 51-10-3, PAR 14, 21, SRM 51-30-1, SRM 51-30-5 AND DOWN 9915558, REV BA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK ON STIFFENER OF BS 1338 AND PROJECTION LONG 15RT AT RT AFT LAVATORY AREA. STIFFENER ABOVE REPORTED WAS DRILLED, TREATED, PAINTED AND REPLACED IAW SRM 51-10-3, PAR 14, 21, SRM 51-30-1, SRM 51-30-5 AND DOWN 9915558, REV BA.