What was found
CORROSION ON RT CUSP WEB UPPER, LOWER SURFACE BETWEEN BS 486 TO BS 501. AREA WAS REPAIRED IAW SRM 53-00-55, FIG 216 AND 51-10-04, PAR 15, 21, 37 UT WAS ACCOMPLISHED NDT SPM 04-00-07, PAR 5, FIG 3, ORIGINAL THICKNESS ON WEB IS 0.020" REMAINING IS 0.010". THEREFORE AREA OUT OF LIMITS IAW SRM 53-00-55, FIG 101. OLYMPUS 38DL PLUS SONOPEN V260 SM 23-JUL-16.