What was found
FWD CABIN FLOOR SUPPORT WEB Y 1732 BETWEEN FRAME 20 AND 21 ATTACH ANGLE PROFILE CORRODED. REMOVED CORROSION IAW SRM 51-22-11, NO LIMITS FOUND ON THE SRM, R & R FLOOR SUPPORT WEB AND ANGLE IAW SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CABIN FLOOR SUPPORT WEB Y 1732 BETWEEN FRAME 20 AND 21 ATTACH ANGLE PROFILE CORRODED. REMOVED CORROSION IAW SRM 51-22-11, NO LIMITS FOUND ON THE SRM, R & R FLOOR SUPPORT WEB AND ANGLE IAW SRM 51-42-11.