What was found
FWD CABIN FLOOR SUPPORT 254 BETWEEN FRAME 18 AND 20 TOP SURFACE HAS 2 AREAS CORRODED. REMOVED CORROSION FOUND TO BE OUT OF LIMITS 1" X .5" 100 PERCENT MATERIAL LOSS. REPLACED FLOORBEAM IAW SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CABIN FLOOR SUPPORT 254 BETWEEN FRAME 18 AND 20 TOP SURFACE HAS 2 AREAS CORRODED. REMOVED CORROSION FOUND TO BE OUT OF LIMITS 1" X .5" 100 PERCENT MATERIAL LOSS. REPLACED FLOORBEAM IAW SRM 51-42-11.