What was found
CORROSION ON COUNTERSINK OF FUEL ACCESS DOOR 620MB. CORROSION WAS REMOVED. COUNTERSINK WERE MEASURED AND WERE FOUND 3 COUNTERSINK OUT OF LIMITS IAW SRM 57-10-01. ACCESS WAS REPAIRED IAW SRM 51-10-01 AND TREATED IAW SRM 51-10-04.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON COUNTERSINK OF FUEL ACCESS DOOR 620MB. CORROSION WAS REMOVED. COUNTERSINK WERE MEASURED AND WERE FOUND 3 COUNTERSINK OUT OF LIMITS IAW SRM 57-10-01. ACCESS WAS REPAIRED IAW SRM 51-10-01 AND TREATED IAW SRM 51-10-04.