What was found
FWD CABIN FLOOR SUPPORT ATTACHED ANGLE PROFILER BETWEEN FRAME 12 AND FRAME 13, BETWEEN 1292 AND 1732, LOWER FLANGE TOP SURFACE CORRODED. BLENDED OUT CORROSION IAW SRM 51-73-00, FOUND 100 PERCENT MATERIAL LOSS, OUT OF LIMITS IAW SRM 53-00-14. R & R ATTACHED ANGLE IAW SRM 51-42-11.