What was found
CRACK ON ANGLE CLIP BELOW OF BEAM 1, FWD EDGE, APPROXIMATELY BS 170 AT FWD SERVICE DOOR, R1. CLIP WAS REPLACED IAW BWG 9911579, REV L AND SRM 51-30-5, SECTION SEAL WAS REMOVED AND INSTALLED IAW AMM 52-41.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK ON ANGLE CLIP BELOW OF BEAM 1, FWD EDGE, APPROXIMATELY BS 170 AT FWD SERVICE DOOR, R1. CLIP WAS REPLACED IAW BWG 9911579, REV L AND SRM 51-30-5, SECTION SEAL WAS REMOVED AND INSTALLED IAW AMM 52-41.