What was found
FOUND ON "OK TO TREAT", L1 DOOR, THRESHOLD, INBD THRESHOLD/FLOORBOARD SUPPORT, 4" FROM DOOR OPENING, CORRODED, IN MULTIPLE AREAS ALONG ENTIRE LENGTH OF SUPPORT. TREATED PRIMED AND PAINTED AND INSTALLED IAW DWG 9936534.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND ON "OK TO TREAT", L1 DOOR, THRESHOLD, INBD THRESHOLD/FLOORBOARD SUPPORT, 4" FROM DOOR OPENING, CORRODED, IN MULTIPLE AREAS ALONG ENTIRE LENGTH OF SUPPORT. TREATED PRIMED AND PAINTED AND INSTALLED IAW DWG 9936534.