What was found
LT INBD ELEVATOR UPPER SKIN PUNCTURED 1.5" X 1.5" AREA 32.25 FROM T/E 10.0 FROM INBD EDGE. REMOVED DAMAGE AT PREPARED AREA FOR CORE INSTALLATION IAW SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LT INBD ELEVATOR UPPER SKIN PUNCTURED 1.5" X 1.5" AREA 32.25 FROM T/E 10.0 FROM INBD EDGE. REMOVED DAMAGE AT PREPARED AREA FOR CORE INSTALLATION IAW SRM.