What was found
CORROSION ON LOWER SILL AT STR 23L LEVEL AT AFT GALLEY AREA BETWEEN FRAME 67 TO FRAME 68, REPLACED LOWER SILL LOC BTW FRAME 66 TO FRAME 68 AT LEVEL STR 23L AFT GALLEY AREA FLOOR STRUCTURE IAW SRM 51-72-11 AND DWG D53480020.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON LOWER SILL AT STR 23L LEVEL AT AFT GALLEY AREA BETWEEN FRAME 67 TO FRAME 68, REPLACED LOWER SILL LOC BTW FRAME 66 TO FRAME 68 AT LEVEL STR 23L AFT GALLEY AREA FLOOR STRUCTURE IAW SRM 51-72-11 AND DWG D53480020.