What was found
LT FUSELAGE GOUGE / DENT 3" X 8" BS 1159, STR 19-20L .0625" DEEP. BLENDED IAW SRM 53-01-01. ACCOMPLISHED HFEC IAW NDT/SPM 06-10-01.001, NO CRACKS NOTED. ACCOMPLISHED INTERNAL GVI, NO DAMAGE NOTED. ACCOMPLISHED UT INSPECTION IAW NDT/SPM 04-00-03. ALODINE AND PRIMED; IDENTIFIED AS ENGINEERING APPROVED IAW ER/A 547070-14. ASSOCIATED ER/A 00-547070 ADDED FOR AC 9562.