What was found
LT FUSELAGE DENT 3" X 2", .0937" DEEP. BS 1159, STR 20-21L. BLENDED IAW SRM 53-01-01. ACCOMPLISHED HFEC IAW NDT/SPM 06-10-01.001, NO CRACKS NOTED. ACCOMPLISHED INTERNAL GVI, NO DAMAGE NOTED. ACCOMPLISHED UT INSPECTION IAW NDT/SPM 04-00-03. ALODINE AND PRIMED; IDENTIFIED AS ENGINEERING APPROVED IAW ER/A 547070-14, REV ORIGINAL. ASSOCIATED ER/A 00-547070 ADDED FOR AC 9562.