What was found
CORROSION SHEAR TIE FRAME 31 ON FLOOR STRUCTURE BETWEEN STR 42R AND STR 43R IN FWD CARGO COMPARTMENT, REPLACED SHEAR TIE FRAME 31 BETWEEN STR 42R AND STR 43R IN FWD CARGO COMPARTMENT IAW SRM 51-72-11 AND DWG D53231533 AND D53231586.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION SHEAR TIE FRAME 31 ON FLOOR STRUCTURE BETWEEN STR 42R AND STR 43R IN FWD CARGO COMPARTMENT, REPLACED SHEAR TIE FRAME 31 BETWEEN STR 42R AND STR 43R IN FWD CARGO COMPARTMENT IAW SRM 51-72-11 AND DWG D53231533 AND D53231586.