What was found
CORROSION SHEAR TIE FRAME 31 ON FLOOR STRUCTURE BETWEEN STR 42L AND STR 43L IN FWD CARGO COMPARTMENT. REPLACED SHEAR TIE, FRAME 31 BETWEEN STR 42L AND STR 43L IN FWD CARGO COMPARTMENT IAW SRM 51-42-11 AND DWG D53231533.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION SHEAR TIE FRAME 31 ON FLOOR STRUCTURE BETWEEN STR 42L AND STR 43L IN FWD CARGO COMPARTMENT. REPLACED SHEAR TIE, FRAME 31 BETWEEN STR 42L AND STR 43L IN FWD CARGO COMPARTMENT IAW SRM 51-42-11 AND DWG D53231533.