What was found
MAIN CABIN BS 377, LBL 25 FLOORBEAM STABILIZER STRAP IS CRACK. REMOVED FASTENERS & DAMAGED SECTION OF STRAP BETWEEN BS 365-377, LBL 25 IAW SRM 53-00-51, REPAIR 12. HFEC INSP OF HOLES AND TRIM OUT IAW NDTM PT6 51-00-19 & 51-00-16 ASSET 15270, NO DEFECTS NOTED. PERFORMED DVI AT BS 365-377 LBL IAW SRM 53-00-51, REPAIR 12, STEP 4G, NO DEFECTS NOTED. FABRICATED, LOCATED, DRILLED & DEBURRED -1 STRAP 7075T6 .040 PO ST-00005636 & -2 FILLER 7075T56 .032 PO ST00006304 IAW SRM 53-00-51, REPAIR 12. ALODINED & PRIMED IAW SRM 51-20-01. INSTALLED -1 STRAP & -2 FILLER AT BS 365-377, LBL 25 IAW SRM 53-00-51, REPAIR 12. NO FURTHER INSPECTION REQUIRED.