As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION STAMPING PANEL ON FLOOR STRUCTURE BETWEEN. FRAMES 28 TO 29 AND STR. 42L TO STR. 44 IN FWD CARGO COMPARTMENT, REPLACED STAMPING PANEL ON FLOOR STRUCTURE BETWEEN FRAME 28 TO FRAME 29 AND STR. 42L TO STR. 44 FWD CARGO COMPARTMENT IAW SRM 51-72-11 AND DWG D53230861.