As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING INSPECTION FOUND EXIT SIGN LIGHT, SLIDE LIGHT, OVERDOOR EXIT SIGN LIGHT AT L2 DOOR INOPERATIVE. MAINTENANCE FOUND BATTERY PACK, M1673, DRAINED. R & R IAW AMM 33-51-06-960-805. OPS TEST SATISFACTORY. ALSO FOUND BATTERY CHARGER NOT WORKING DURING TEST. R & R IAW AMM 33-51-06-960-806. OPS TEST OK.