What was found
CORROSION ON LONGERON 29LT AND SPLICE FROM BS Y=929 TO 1022 AT AFT CARGO COMPARTMENT, C2, SM. CORROSION WAS REMOVED, REWORKED AREA WAS TREATED, PAINTED, MEASURED, ORIGINAL THICKNESS: 0.125" REMAINING THICKNESS 0.110" THEREFORE IT'S WITHIN LIMITS IAW SRM 51-10-04, PAR 26, 21 AND 15 53-00-00, FIG 103. DUE TO EXCESSIVE CORROSION LONGERON ON BS Y=970 TO 1010 AND SPLICE WERE REPLACED IAW SRM 53-00-05, FIG 201, 51-41-02, AND 51-40-05. EQUIPMENT: PANAMETRICS 35DL PLUS TRANSDUCER SONPEN V260RM EXP DATE 25AUG16.