What was found
CORROSION IN SEVERAL SPOTS ON ENTRY WAY FLOOR SUPPORT UPPER SURFACE BS 1664-1681 INBD OF R4 THRESHOLD. EVALUATED MAIN CABIN FLOOR SUPPORT, STA 1664-1681 FOUND TO BE 100 PERCENT MATERIAL LOSS AND IS BEYOND LIMITS IAW SRM 53-00-51. LOCATED DRILLED AND DEBURRED NEW FLOOR SUPPORT, PN 146N5246U6, PO 664DN-00041 IAW DWG 146N5230, REV: D. INSTALLED NEW FLOOR SUPPORT, STA 1664-1681 IAW SRM 51-40-02 AND DWG 146N5230, REV: D.