What was found
MAIN CABIN CUSP WEB CORRODED BETWEEN BS 1020-1040, RT SIDE CP53-241-01I. REMOVED CORROSION MAIN CABIN CUSP WEB STA 1020-1040, RT SIDE IAW SRM 51-10-02. EVALUATED AREA ORIGINAL THICKNESS .063, REMOVED .034, REMAINING .029 FOUND TO BE OUT OF LIMITS IAW SRM 53-40-13. FABRICATED NEW WEB FROM .063, 7075-0 AND HEAT TREATED TO T-6 CONDITION IAW DWG 144N5140, REV: AB. LOCATED DRILLED AND INSTALLED NEW WEB IAW SRM 51-40-02 AND DWG 144N5140, REV: A.