What was found
CRACKED INNER PAN ON FWD EDGE AND BEAM NR 1 AT FWD CARGO COMPARTMENT DOOR. DAMAGE ON PAN, CRACKS 0.-906" AND 1.375" WERE STOPPED IAW SRM 51-01, PAR 21. NOTES: NEW DOUBLER WAS FABRICATED IAW SRM 52-03D, FIG 8 AND 51-10-2. WEIGHT REPAIR PARTS=0.992 LB, NEW DOUBLER WAS INSTALLED IAW SRM 51-30-2, 51-30-5, AND ERA 539918-14, REV ORIGINAL.