What was found
CORROSION ON WEB FROM STA Y=1361 TO CANT 1485 AT VENTRAL STAIRWAY SHROUD ACCESSORY COMPARTMENT. THE MEASURES AFTER REMOVED CORROSION ON AREAS LOCATED AT STA 825.808, 905.902 + 11", MEASURE REMAINING THICKNESS AFTER REWORK IS 0.038" AND ORIGINAL THICKNESS IS 0.040", THEREFORE IS WITHIN LIMITS IAW ERA 511165-14MA, REV C. THE SECTION LOCATION 905.902+11" AT STA 960.000 MUST BE REPAIRED BECAUSE THE CRACKS ARE WITHIN LIMITS. THE AREA OUT OF LIMITS WAS REPAIRED IAW SRM 53-01, FIG 4, SHEET 4, PAGE 25 AND 51-30-2 EQ 38DLP-90-SM-U-MT-E-ES EXP DATA 22-JUL-16 N/C 1201 AND TRANSDUCER V260-RM.