What was found
FORWARD CABIN FLOOR STRUCTURE AT FRAME 20, Y-1732, FORWARD END TOP SURFACE CORRODED. LOCATED AND DRILLED IAW SRM 51-42-12. INSTALLED NEW FWD CABIN FLOOR STRUCTURE WEB AT FRAME 20, Y-1732 IAW SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FORWARD CABIN FLOOR STRUCTURE AT FRAME 20, Y-1732, FORWARD END TOP SURFACE CORRODED. LOCATED AND DRILLED IAW SRM 51-42-12. INSTALLED NEW FWD CABIN FLOOR STRUCTURE WEB AT FRAME 20, Y-1732 IAW SRM 51-42-11.