What was found
CRACKED STOP FITTING NR 2 FORWARD EDGE AND 5 AFT EDGE BEAM PROJECTION AT FORWARD CARGO COMPARTMENT DOOR. STOPS NR 2 AND 5 WERE REPLACED IAW SRM 51-30-1 AND 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED STOP FITTING NR 2 FORWARD EDGE AND 5 AFT EDGE BEAM PROJECTION AT FORWARD CARGO COMPARTMENT DOOR. STOPS NR 2 AND 5 WERE REPLACED IAW SRM 51-30-1 AND 51-30-5.