What was found
CRACK ON ANGLE IN AFT EDGE NR 1 BEAM AT EMERGENCY DOOR RT FWD. A NEW ANGLE WAS FABRICATED IAW SRM 51-10-2, AND DWG 9957735 REV. G. THE ANGLE WAS REMOVED AND REPLACED IAW SRM 51-30-2, AND SRM 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK ON ANGLE IN AFT EDGE NR 1 BEAM AT EMERGENCY DOOR RT FWD. A NEW ANGLE WAS FABRICATED IAW SRM 51-10-2, AND DWG 9957735 REV. G. THE ANGLE WAS REMOVED AND REPLACED IAW SRM 51-30-2, AND SRM 51-30-5.