What was found
EXCESSIVE CORROSION ON RT CUSP WEB STA Y=401 IN REF CARD 24, ZONE 200, CARD 78, ZONE 200. DUE EXCESSIVE DAMAGE WAS REPAIRED IAW SRM 53-00-55 FIG 225, SHEET 7 OF 10. HFEC INSPECTION WAS ACCOMPLISHED ON RT CUSP WEB, STA Y=401, NO CRACKS WERE FOUND AFTER TRIMMING OUT IAW NDT SPM 06-10-01.001, PHASE C2D, CN 925. RII COMPLETED.