What was found
CRACKED CHANNELS ON FLOOR PANELS NRS 541F, 927E, 1003F, 313A, AND 256A AT CAB PAX. CRACKS ON FLOOR PANELS WERE REPAIRED IAW SRM 53-05, FIG 131B & 131C AND 51-30-02. LONG OF CRACKS 541F=0.125", 927E=0.093", 1003F=0.140", 313A=.200", AND 256A=0.170".