What was found
DURING INSPECTION FOUND AFT WET AREA, BS 967 STRINGER CLIP 19R. MAINTENANCE REMOVED AND REPLACED THE STRINGER CLIP IAW SRM 51-40-02 PAGE 2-3, SRM 51-40-05 PAGE 5, SRM 51-20-01 PAGE 4-14, AMM 51-21-00 PAGE 1-3 DRAWING 147A3500 PL AND 147A0020.