What was found
FLOOR WEB FORWARD WET AREA, RIGHT SIDE, BS 175-180, RBL 40-44. CORRODED. FOUND TO BE OUT OF LIMITS. REPLACED IAW SRM 53-00-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR WEB FORWARD WET AREA, RIGHT SIDE, BS 175-180, RBL 40-44. CORRODED. FOUND TO BE OUT OF LIMITS. REPLACED IAW SRM 53-00-01.