What was found
FWD WET AREA RIGHT SIDE BS 256 RBL 22 - 44 FLOORBEAM CORRODED ON UPPER SURFACE. REMOVED CORROSION AND FOUND OUT OF LIMITS IAW SRM 53-00-01 FIG 3. REMOVED AND REPLACED IAW SRM 51-30-05 VOL II.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD WET AREA RIGHT SIDE BS 256 RBL 22 - 44 FLOORBEAM CORRODED ON UPPER SURFACE. REMOVED CORROSION AND FOUND OUT OF LIMITS IAW SRM 53-00-01 FIG 3. REMOVED AND REPLACED IAW SRM 51-30-05 VOL II.