What was found
CORROSION ON RT WING LOWER SKIN XRS 115. FAIRING WAS REMOVED, AREA WAS BLENDED, MEASURE (UT) NDT SPM 04-00-07 PAR 5 FIGURE 3 SHEET 1 & 2 WAS ACCOMPLISHED WITH ORIGINAL .340" MINIMUM REMAINING .333" AND FOUND WITHIN LIMITS, FLAP PENNING WAS PERFORMED, TREATED AND PAINTED IAW SRM 57- 03D FIGURE 30 SHEET 1, PS 900-4 05 AND SRM 51-30-1.