What was found
AFT CARGO COMPARTMENT BILGE AREA DOOR CUTOUT, BS 1212 - 1269 LOWER SILL WEB CORRODED. FOUND TO BE OUT OF LIMITS. REPLACED FLOOR SUPPORT FROM IAW SRM 51-30-02 AND DWG 5936442.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO COMPARTMENT BILGE AREA DOOR CUTOUT, BS 1212 - 1269 LOWER SILL WEB CORRODED. FOUND TO BE OUT OF LIMITS. REPLACED FLOOR SUPPORT FROM IAW SRM 51-30-02 AND DWG 5936442.