What was found
CRACK ON BEAM NR 7, STA 162.5 AT FWD PASSENGER DOOR STRUCTURE, SM, CARD 15, ZONE 820. CRACK ON BEAM NR 7 WAS REPAIRED IAW SRM 52-10-02, FIG 202. HFEC INSPECTION WAS ACCOMPLISHED NO CRACKS WERE FOUND AFTER STOP DRILL IAW NDT SPM 06-10-01.001. CRACK LONG .750" PHASEC 3D C/N: 1381 EXP DATE: 20OCT16. RII COMPLETED.