What was found
CORROSION ON COUTERSINKS AT FUEL TANK ACCESS NR 520JB, SM. CORROSION OF COUNTERSINK WAS REMOVED IAW SRM 51-10-04. REWORKED AREAS WERE MEASURED AND MAX DIAMETER ALLOWABLE IS 0.532" AND 5 ADJACENT HOLES OUT OF LIMITS WERE FOUND. MAX DIAMETER MEASURED IS 0.557", IT IS OUT OF LIMITS IAW SRM 57-10-01. ACCESS PLATE WAS REPLACED AND PN VERIFIED IAW AIPC 57-27-01.