What was found
LIGHTNING STRIKE BS 604 ABOVE STRINGER 12R. BURNISHED AREA. PERFORMED HFEC INSPECTION OF BLENDED AREA IAW ERA 549836-14, REV. ORIG, SEC 1 STEP 2. NO CRACKS INDICATED. C/W STEPS 3 AND 4 OF ERA 549836-14, REV. ORIG, SEC. 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LIGHTNING STRIKE BS 604 ABOVE STRINGER 12R. BURNISHED AREA. PERFORMED HFEC INSPECTION OF BLENDED AREA IAW ERA 549836-14, REV. ORIG, SEC 1 STEP 2. NO CRACKS INDICATED. C/W STEPS 3 AND 4 OF ERA 549836-14, REV. ORIG, SEC. 1.