As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING INSPECTION FOUND AFT CABIN FLOOR, STR 17 CREASE BEAM INNER CHORD HAS UPPER SURFACE CORROSION JUST INBD OF DOOR 2R THRESHOLD FROM BS 947-986+10". MAINTENANCE REMOVED CORROSION FROM R2 DOOR CREASE BEAM IAW SRM 53-70-15. FOUND OUT OF LIMITS, ORIGINAL .080", REMAIN .045", LOSS .035" IAW SRM 53-70-15. R & R IAW DWG 147A5700.