What was found
AWR: CORROSION ON COUNTERSINKS AND SETTLEMENT AREA AT FUEL TANK ACCESS NR 1414C AND NR 1462C. ACCESS PLATE 1414C AND 1462C WERE CLEANED, BOTH ACCESS PLATES HAD 3 COUNTERSINKS ADJACENT OUT OF LIMITS, THEREFORE WERE REPLACED IAW SRM 51-22-2A, PAR 6, CONDITION II ACCESS PLATE NR 1434C WAS REMOVED AND INSTALLED ON NEW ACCESS PLATE 1414C. IAW AMM 28-00-00.