What was found
CRACK ON GENERATION FLOOR CHANNEL NR 221, TF, SM, NRC 00226. CRACK WAS STOP DRILLED. DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 51-41-02, SRM 51-20-09, AND SRM 53-20-50, REPAIR 5, FIG 202. HFEC INSPECTION WAS PERFORMED AT END OF CRACK. NO CRACKS WERE FOUND BEYOND IAW NDT SPM 06-10-01.001 EQUIPMENT.