What was found
AWR HIDDEN DISCREPANCY: CRACKED PAN JUST ON SEATING AREA OF STOP FITTING PROJECTION BEAM 4, FWD SIDE, AT FWD CARGO DOOR. CRACK ON PAN JUST ON SEATING AREA OF STOP FITTING PROJECTION BEAM 4, FWD SIDE, WAS REPAIRED IAW SRM 52-05-D, FIG 50.