What was found
CRACKED FRAME STA 1225 CANT AND 7 HRS POSITION AT AFT ACCESSORY COMPARTMENT, SM, SN 00519. HFEC WAS ACCOMPLISHED, 01 CRACK WERE FOUND OF 1.65" IAW MD NDT SPM 06-10-01.001. VISUAL INSPECTION WAS PERFORMED NOT DISCREPANCIES WERE FOUND HFEC INSPECTION WAS ACCOMPLISHED ON TRIM OUT AREA, NO CRACKS WERE FOUND IAW ETI-17-16-116, STEP 4 EQUIPMENT USED ON STEP 5. REPAIR PARTS WERE INSTALLED ER/A 550288-14, REV ORIGINAL.