What was found
CENTER FLOOR PANEL SUPPORT AT STA 636 IS CRACKED. MARKED, PULLEY CLUSTER AT STA 636 REMOVED IAW SRM 51-41-01, PG 1. INTERCOSTAL REMOVED IAW SRM 51-41-02. MATERIAL VERIFICATION IS 7075-T6 .050 IAW MFG PROPRIETARY DWG 9936580, REV B. ALODINED AND PRIMED IAW SRM 51-22-01. HOLES LOCATED AND DRILLED IAW SRM 51-40-08, PAGE 1, STEP 3. INSTALLED NEW, L BRACKET IAW SRM 51-41-02, PG 1, STEP 4, 51-41-05, PG 1, STEP 3. INSTALLED PULLEY CLUSTER AT STA 636 IAW SRM 51-41-01. ROUTE AND RIG CHECK OK IAW AMM 28-22-24-830-801. FABRICATED L-ANGLE DOUBLER IAW SRM 53-00-00, FIG 201, REPAIR 1, PAGE 202, ITEM 3, TAG 2892.