DURING INSPECTION, FOUND FORWARD WET AREA, L1 CREASE BEAM CORRODED AT BS 344 TO 360 LBL 60. MAINTENANCE REPLACED THE CREASE BEAM IAW SRM 51-40-02, 51-40-05, AND DRAWING 141A8112 REV E.