What was found
CORROSION ON FLOORBEAM +Y254 AT FORWARD GALLEY AREA FROM FRAME 12 TO FRAME 24, L=0.775", W=0.325", D=0.001". REPLACED FLOORBEAM +Y254 AT FORWARD GALLEY AREA FROM FRAME 12 TO FRAME 24 IAW SRM 51-72-11 AND DWG D53112816, D53110984.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOORBEAM +Y254 AT FORWARD GALLEY AREA FROM FRAME 12 TO FRAME 24, L=0.775", W=0.325", D=0.001". REPLACED FLOORBEAM +Y254 AT FORWARD GALLEY AREA FROM FRAME 12 TO FRAME 24 IAW SRM 51-72-11 AND DWG D53112816, D53110984.