What was found
DURING INSPECTION FOUND AFT CARGO FLOOR SUPPORT DENTED ON UPPER SURFACE AT 727E LBL3. MAINTENANCE LOCATED AND DRILLED REPAIR PARTS AT BS 727E LBL3 2EA, 2 CHANNEL SPLICES AND 1 EA FLOORBEAM CHANNEL IAW SRM 53-00-53 REPAIR 4 FIG 201 SHT 1. THE INSTALLATION FOR THE REPAIR PARTS AT BS 727E LBL3 WAS ACCOMPLISHED ON W/C 34597/1600 /0017.