What was found
PUNCTURE ON RT CUSP WEB BS 813 BETWEEN X40 TO 44). THE DAMAGE WAS REMOVED IAW SRM 53-00-55 REPAIR 4 FIG. 219, HFEC INSPECTION WAS ACCOMPLISHED AFTER TRIM OUT, AND NO CRACKS WERE FOUND IAW NDT SPM 06-10-01.001. A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 55- 00-55 FIG 219,51-41-02.