As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CRACK ON PAN BS 427 BETWEEN BEAM 1 AND BEAM 2 AT FWD CARGO DOOR. HFEC INSPECTION WAS ACCOMPLISHED AND CRACKS WERE FOUND IAW NDT SPM 06-10-01 .001. CRACKS ON PAN WERE STOP DRILLED IAW SRM 52-30-02 FIG 201, HFEC WAS ACCOMPLISHED ON PAN AND NO CRACKS WERE FOUND AFTER STOP DRILL IAW NDT SPM 06-10-01.001.