What was found
DURING INSPECTION FOUND CABIN FLOORBEAM STATION 328 RBL 48 CORRODED. MAINTENANCE REPAIRED FLOORBEAM 328 FROM BL0 TO RBL 60" IAW SRM 53-10-51 REPAIR 7.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION FOUND CABIN FLOORBEAM STATION 328 RBL 48 CORRODED. MAINTENANCE REPAIRED FLOORBEAM 328 FROM BL0 TO RBL 60" IAW SRM 53-10-51 REPAIR 7.