What was found
DURING INSPECTION FOUND R1 DOOR CREASE BEAM HAS CORROSION IN MULTIPLE AREAS. MAINTENANCE REMOVED AND REPLACED R1 CREASE BEAM IAW DWG 141A8310 REV - & SRM 51-40-02 PARA 4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION FOUND R1 DOOR CREASE BEAM HAS CORROSION IN MULTIPLE AREAS. MAINTENANCE REMOVED AND REPLACED R1 CREASE BEAM IAW DWG 141A8310 REV - & SRM 51-40-02 PARA 4.