What was found
CORROSION LEVEL 2 AT FWD CARGO STA 654 BETWEEN S-39L AND S-39R SHEAR TIE CORROSION. REMOVED AND MEASURED CLEAN UP DEPTH IN THE SHEAR TIE SURFACE 0.008" ORIGINAL THICKNESS IS 0.050" FOUND OUT OF LIMIT AS PER SRM 53-00-07. REPLACED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION LEVEL 2 AT FWD CARGO STA 654 BETWEEN S-39L AND S-39R SHEAR TIE CORROSION. REMOVED AND MEASURED CLEAN UP DEPTH IN THE SHEAR TIE SURFACE 0.008" ORIGINAL THICKNESS IS 0.050" FOUND OUT OF LIMIT AS PER SRM 53-00-07. REPLACED.